Solar power plant control: PPC, DEWA D33 and Shams Dubai

Power plant controllers that meet DEWA's D33 requirements, rooftop solar to Shams Dubai standards, and the SCADA, battery and hybrid control around them.

DEWA D33 Solar PV Initiative

D33-ready solar plants, with the controller DEWA requires

DEWA's D33 Solar PV Initiative lets eligible industrial companies, agri-tech enterprises and data centres in Dubai build captive solar up to their maximum demand. Every D33 plant needs a power plant controller that DEWA can command.

Who it is for

Industrial companies, agri-tech enterprises and data centres holding a D33 eligibility certificate, issued jointly by DET, the Department of Finance and DEWA and valid for 10 years.

What it allows

Captive solar PV up to the site's maximum demand, in addition to what Shams Dubai allows, under DEWA's D33 Industry Friendly Power Policy.

Connection

Plants with a maximum continuous active power above 0.4 MW connect to the MV network, following DEWA's DRRG plant segmentation.

Plant control

A power plant controller is mandatory, and the D33 monitoring and control specification applies in place of the general DRRG monitoring requirements.

What D33 asks of the plant control
Mandatory power plant controller

One controller makes the whole PV plant respond as a single unit at the point of connection.

Ramp-rate control

Active power changes limited to 10 % of the plant's installed capacity per minute.

Reactive power capability

Units above 400 kW on the MV network provide reactive power across a semi-circular P-Q capability curve.

DEWA control interface

Set-points and commands from DEWA control centres, with plant measurements returned for monitoring.

PPC architecture
set-pointstelemetryDEWA control centreset-points and commandsPower plant controllerP, Q, V, PF, ramp 10 % / minPOI meterP, Q, V, fPlant SCADAhistorian, reportsPV invertersMV blocksBattery storageBESS PCSGeneratorshybrid sites

Ramp-rate control, illustrated

40 %60 %80 %100 %0 min1 min2 min3 min4 min5 min6 minDEWA set-point 60 %Plant output, 10 % per minute

Illustrative only. The plant follows a DEWA set-point change at 10 % of installed capacity per minute.

What DIS delivers for D33

  • Compliance review of the single-line diagram, inverters and protection against the D33 documents
  • PPC design, configuration and factory testing on Inavitas, Siemens SICAM A8000 or Allen-Bradley ControlLogix
  • Interface to the DEWA control centre, revenue metering and the plant SCADA
  • Ramp-rate, curtailment and reactive power tests at commissioning, with signed records
  • Compliance documents and support through DEWA inspection and energisation

Summarised from DEWA's D33 Solar PV Initiative documents, including the D33 Monitoring and Control Requirements and the D33 Connection Conditions (V1.1, November 2025). DEWA's published documents prevail.

Power plant controller

One controller for PV, batteries and generators

The PPC sits between the grid operator and the plant. It reads the point of connection, then commands inverters, battery storage and generators so the whole site behaves as one unit to the grid code.

Active power control

Export limits, curtailment and ramp rates at the point of connection.

Reactive power and voltage

Q, power factor and voltage control modes to the grid code.

Frequency response

Active power reduction during over-frequency events.

Battery coordination

Smoothing, firming, time shifting and peak shaving with BESS.

Hybrid with generators

Minimum genset loading and fuel saving for camps and off-grid sites.

Data and reporting

Historian, availability and performance ratio reports for the owner.

Controller platforms

Inavitas PPC and SCADASiemens SICAM A8000Allen-Bradley ControlLogixDEIF AGC-150Emerson PACSystems
Shams Dubai

Rooftop solar on homes, buildings and facilities

Shams Dubai is DEWA's net-metering programme: owners install rooftop solar, use the energy on site and export the surplus to the DEWA grid. We deliver it with DOME Group's solar EPC company, a DEWA-approved solar contractor.

Survey and design

Roof survey, shading and yield study, and design to DEWA DRRG standards and connection guidelines.

DEWA approval

Design submission through a DEWA-enrolled solar contractor, with inverters and protection from DEWA's approved lists.

Installation

Modules, mounting, inverters, DC and AC protection, earthing and cabling.

Inspection and connection

DEWA inspection and testing, net meter installation and connection to the grid.

Monitoring and O&M

Inverter monitoring, module cleaning, preventive maintenance and performance reports.

PPC and SCADA cabinets at factory test, 40 MW hybrid solar plant
PPC and SCADA cabinets at factory test, 40 MW hybrid solar plant
Solar plant inverter station during installation
Solar plant inverter station during installation
Hybrid plant SCADA: gensets, solar and battery storage
Hybrid plant SCADA: gensets, solar and battery storage

Planning a D33 or Shams Dubai solar plant?

Send the single-line diagram and inverter list. We will check them against DEWA's requirements and propose the PPC.